Posts

Showing posts from December, 2014
Image
Image
Replace your wired Serial/USB programming cable!

Wireless series PLC Cable

1.Support FX series PLC (FX0 FX0N FX2N FX1N FX1S FX0S FX3U and all Mitsubishi round 8-pin RS422 port)

2.Support Windows XP WIN7

3.Support line, depending on each other, no shelter, no shielding, open area, 10 m wireless transmission distance
http://chinaplccenter.com/PLC-programmer-Cable/Wireless-plc-Programming-cable/Wireless-Bluetooth-programming-cable-USB-SC09-FX-for-Mitsubishi-fx-plc-distance-10m


How to display text messages with Siemens Logo?

https://www.youtube.com/watch?v=CTaLcVasNDM
Image
ONE of the most popular cable in our Store!!!

PC Adapter USB/MPI for Siemens S7-200/300/400 PLC DP/PPI/MPI/Profibus win7 64bit

http://chinaplccenter.com/PLC-programmer-Cable/Siemens-PLC-Cable/PC-Adapter-USB-MPI-for-Siemens-S7-200-300-400-PLC-DP-PPI-MPI-Profibus-win7-64bit
Image

Mitsubishi plc communication test

When you are ready to communicate via AJ71QE71 before beginning GPPW communications Mitsubishi PLC's first implementation of ping program in MS-DOS mode to check whether the connection is correct. Support through the serial port to communicate with the Wei Lun touch screen.
The following shows can communicate
C: \ ping 192. 168. 0. 2
Reply from 192. 168. 0. 2: bytes = 32 time <10ms TTL = 32
The following shows the communication can not
C: \> ping 192. 168. 0. 2
Request timed out.
If the ping does not pass, the connection between the IP address and check the cable and modules, and other settings in WINOOWs.
[Link destination specified screen]
• Ethernet module routing settings screen (only QnA series)
a) network number
Connected to Ethernet assigned a network number.
The network number must be specified by the PLC connected to the network parameters is consistent in number, and in MELSECNET / 10 and Ethernet is a unique number.
b) station number (personal computer station num…

Mitsubishi FX Series PLC general purpose timer works

Image
When the timing condition is ON,
The Timer
PLC internal 100ms, 10ms, 1ms cumulative count clock pulses,
The current value is equal to the set value,
Timers normally open contact connected,
NC

Disconnected.
When the timing condition becomes OFF,
Timer is reset,
Normally open

Disconnected,

NC

Connected,
The current value to zero.

Image
50A/100A 75mv shunt DC ammeter shunt

http://chinaplccenter.com/50A-100A-75mv-shunt-DC-ammeter
Image
New Arrival!

FX2N 92MR/92MT 46 input 46 output RS232 and RS485 PLC 2 analog input 2 analog output

http://chinaplccenter.com/CHINA-PLC/EC2N-PLC?product_id=1022
Image
New Arrival!

500MW DIY mini laser engraving machine laser marking machine engraving machine engraving graphic 17*20CM

http://chinaplccenter.com/CHINA-PLC/CNC/500MW-DIY-mini-laser-engraving-machine-laser-marking-machine-engraving-machine-engraving-graphic

Image
Blue laser 300MW desktop DIY mini laser engraving machine Printer marking machine engraver free shipping with DHL, EMS

http://chinaplccenter.com/CHINA-PLC/CNC/500MW-laser-power-DIY-mini-laser-engraving-machine-Mini-marking-machine